International Journal of Power System Operation and Energy Management IJPSOEM

ISSN: 2231-4407

journal

Abstracting and Indexing

Crossref logo
IIMT Bhubaneswar

IJPSOEM

Comparison of Power flow Enhancement for varying loads usingdifferent Controllers


Niharika Agrawal Ms
Ghousia College of Engineering

Faheem Ahmed Khan Dr
Ghousia College of Engineering

Mamatha Gowda Dr.
BGS College of Engineering and Technology


Abstract

The power demand is continuously increasing due to population growth and changes in lifestyle. Due to shortage of generation and transmission facilities it is desired to increase the existing transmission line power transfer capacity in order to meet the rising demand. Fixed capacitors(FC) and TCSC FACTS device are used to increase the power flow of the line .The advantage in TCSC is that it provides variable compensation instead of fixed compensation by FC. In the present work the comparison of power flow enhancement by fixed capacitors , single TCSC and two modules of TCSC is done for three cases . The three cases are load is suddenly increased and decreased, load is suddenly decreased and increased, load is increased and then further increased. Various Power quality issues like voltage sag ,voltage swell are discussed. The THD voltage and receiving end voltage with different controllers/devices are shown. The power flow is more with TCSC in the system than with FC. The power flow is further enhanced using two modules of TCSC in the system.

Recommended Citation

  1.  Kusum Arora, SK Agarwal Narendra Kumar Dharamveer, “Simulation Aspect of Thyristor Controlled Series Compensator in Power System,” IOSR Journal of Engineering, vol.3, Issue -4, pp. 17-26, April 2013.
  2. Bhakti S Nitve, “Modelling, Simulation and Analysis of Thyristor Controlled Series Capacitor (TCSC),” Journal of Smart Grid Technology, vol.2, Issue-2, pp. 1-14.
  3. Sunita Tiwari, S.P. Shukla, “Compensation by TCSC in open loop control system,” International Journal of Advanced Engineering Technology, vol.3, Issue-1, pp.175-179, Jan-March 2012.
  4. Sangeetha AP. S. Padma, “Study of Thyristor Controlled Series Compensator for the Enhancement of Power Flow and Stability,” International Journal of Scientific and Engineering Research, vol. 5, Issue-4, pp.112-117, April 2014
  5. Sangeetha A. P., S. Padma B. Thiyaneswaran, “HDL based Control Circuit for Power Flow Regulation of TCSC,” Proceedings of the International Conference on Advancement in Electrical and Electronics Engineering, pp.c20-c24, January 2015.
  6. K. Manjusha,S. Balamurugan, N.Krithika, “Real Power Flow Control in Transmission System using TCSC,” Biennial International Conference on Power and Energy Systems: Towards Sustainable Energy (PESTSE),2016.
  7. Pavan Kumar Shirur, Aravind Patil, D Venkatesh, “Modelling and Simulation of Thyristor Controlled Series Compensator connected with Single Source Transmission Line, “School of Electrical Engineering.
  8. Deepa Choudhary “Enhancement of Power System Voltage Stability Using SVC and SSSC,” International Journalof Scientific and Engineering Research, vol.4, Issue-1, pp.1-6, Jan- 2013.
  9. Anil Kumar, Jyoti Shrivastava,” Modelling of Power System for improving stability using Thyristor Controlled Series Capacitor,” International Journal of Science, Engineering and Technology Research, vol.5, Issue-5, pp.1434-1438, May 2016.
  10. Satvinder Singh, Pawan Kumar, Atma Ram, “Modelling and Analysis of Thyristor controlled Series Capacitor using MATLAB/Simulink,” International Journal of New Innovations in Engineering and Technology (IJNIET), vol.1, Issue-3, pp.61-66, February 2013.
  11. Pravin G. Dhawale, Sandip S. Godhade, “Design and Implementation of TCSC for Power Flow Enhancement”.
  12. Anita Kanwar, Rachit Saxena, “Behaviour of TCSC in transmission line using MATLAB/Simulation,” International Journal of Innovative Research in Electrical, Electronics, Instrumentation and Control Engineering, vol.2, Issue -5, pp.195- 197, May 2015.
  13. G.V.T. Prudhviraj, Raghu, S. Meikandasivam and D. Vijayakumar, “Implementing TCSC Device in Kalpakam-Khammam Line for Power Flow Enhancement,” “International Conference on Circuits, Power and Computing Technologies, pp.138-141, 2013.
  14. Dhanush Patel, Kashyap Detroja, Mohit Patel, Krunal Rana, Praful Chudasama, “Voltage Stability Improvement using Thyristor Controlled Series Capacitor,” International Journal of Electrical and Electronics Engineering, vol.3, Issue-5, pp.1-3, May 2016.
  15. Yadu Ram,Dr.Dharmendra Kumar Singh, Amit Agrawal, “Voltage Profile improvement with Thyristor controlled series capacitor, ”International Journal of Advanced Research in Electrical, Electronics and InstrumentationEngineering, vol.4, Issue-6, pp.4999- 5005, June 2015.
  16. Uma Rathore, Dharmendra Kumar Singh “A Study to Improve the Power Quality of Transmission Line Using TCSC,” International Journal of Engineering Science and Computing, vol.6, Issue-3, pp.2396-2399, March 2016.
  17. Lukesh Kumar Sahu, Ankit Dubey, Shruti Soni, “Power Quality Improvement by Using TCSC,” International Journal of Research Studies in Science, Engineering and Technology, vol. 1, Issue-2, pp.56-59, May 2014.
  18. A Sivasankar, T.S.Sirish, “Real Power Flow Control in Transmission Line Using TCSC with Fuzzy Controller,” International Journal of Engineering Research and Application,vol.7, Issue9, pp.55-60, Sept 2017.
  19. D.Chatterjee, A.Mitra,”Simulink based three phase closed loop power flow control using TCSC,” International Journal of scientific research and management,vol.3,Issue-4,pp.2644- 2651,2015.
  20. Kailash Bharatbhai Khimsuriya,Mehul Dansinh Solanki,” Power Transfer capability Improvement of transmission line using TCSC,” International Journal for Scientific Research and Development,vol.4,Issue-02,pp.1428- 1431,2016.

Download pdf viewer for your browser, if the PDF cannot be displayed.